Check Your Tank’s Venting Before Freezing Weather Arrives
When preparing a fuel tank for winter, include its venting equipment in the maintenance plan, including both normal pressure-vacuum vents and emergency vents. Frozen moisture around the openings or moving parts can interfere with airflow or prevent vent mechanisms from moving freely, so all vents deserve a closer look before temperatures drop.
Emergency vents for fuel tanks on backup generators require inspection even when the generators are rarely used. Temperatures continue to fluctuate while the generator is idle, and long periods between deliveries do not remove the need to inspect its fuel tank’s emergency vent.
Freezing Weather Can Interfere With an Emergency Vent
Frozen moisture or debris can restrict an opening or interfere with a vent’s mechanism movement. An emergency vent depends on an unobstructed discharge path and moving parts that must be free to operate.
An emergency vent that sticks in a closed position could leave the tank without its intended emergency relief capacity. A vent that cannot reseat properly could lose its seal. These are reasons to inspect exposed equipment after freezing precipitation, although the likely problems depend on the particular design and installation.
Ask the manufacturer about the vent’s minimum service temperature and UL listing. Specify the vent’s location in that conversation. Any winterization measures must follow the manufacturer’s instructions for the selected model.
Pressure-Vacuum Venting Handles Everyday Tank Breathing
Fuel delivery displaces air from a tank, while fuel withdrawal requires air to enter. Heating and cooling also change the pressure inside. A pressure-vacuum vent opens at its specified pressure or vacuum setting to accommodate that normal inbreathing and outbreathing. These vents also have moving parts, so moisture and icing can interfere with normal operation here as well.
An emergency vent provides relief for abnormal tank pressure, including exposure to fire. It does not provide routine pressure relief, so your tank needs the appropriate equipment for both normal inbreathing and outbreathing, and emergency pressure relief.
When comparing emergency vents, review the whole tank’s venting requirements with the manufacturer. The opening pressure and rated flow capacity must meet the tank, and a larger connection alone does not confirm that a vent meets the required relief capacity.
Compare the 89 and 1700 Pressure/Vacuum Relief Products
The 89 pressure-vacuum vent, offered by Clay & Bailey as a BJE/Husky dealer, uses separate diaphragm-operated pressure and vacuum valves. Review the 89 spec sheet for its settings and venting capacity.
The 1700 pressure-vacuum dome provides pressure-vacuum relief and tank access through a 24-inch manway. Its large size serves larger tank applications. Review the 1700 spec sheet with Clay & Bailey and confirm the dome’s suitability for the tank and stored product.
Match the Emergency Vent to Your Tank’s Requirements
Within Clay & Bailey’s emergency vent line, the 366 slimline vent has a 4-inch female NPT connection and a profile intended for limited space. The 369 emergency pressure relief vent has a mushroom-style weather deflector and comes in 4-, 6-, and 8-inch sizes. Available space and tank connections will help narrow the selection for your application.
Use the Venting Guide to review vent sizing and capacity, including differences between screened and unscreened options. Then confirm the required relief capacity and opening pressure for the specific tank with the manufacturer. Include the applicable project requirements when requesting a recommendation.
Clay & Bailey’s emergency vent product families are evaluated and listed by UL under File MH25085 in accordance with ANSI/CAN/UL/ULC 2583, a joint American National Standard and National Standard of Canada.
Keep Inspection on the Schedule for Idle Generator Tanks
Clay & Bailey’s emergency vent installation and maintenance instructions call for daily visual checks for obstructions and a check before tank filling. They also specify quarterly inspections.
Follow those instructions with qualified personnel for the required service work, and keep the tank vents on the maintenance schedule between generator runs. A generator exercise does not replace the vent inspections as specified by its manufacturer.
Ask Clay & Bailey about inspection requirements for the vents on your generator tank.
Review Your Emergency Vent Selection With Clay & Bailey
Choosing an emergency vent for your fuel tank requires knowledge of your tank details and expected operating conditions. Call on Clay & Bailey’s tank venting expertise, so we can discuss an emergency vent that meets your tank’s connection, clearance, and relief-capacity requirements. Ask us to review the emergency vents on your backup generator tanks, alongside the required normal pressure-vacuum equipment.
Call (800) 821-6583 or send us your tank information to request a vent recommendation and quote.